Re: [tkined] Scotty + Traps

Juergen Schoenwaelder (schoenw@ibr.cs.tu-bs.de)
Wed, 17 Mar 1999 12:14:34 +0100

>>>>> Sean Watkins writes:

Sean> In my SNMP book, it describes the Get/Set Message and also the
Sean> Trap message. The trap messages PDU includes 2 additional
Sean> fields

Sean> 1) is a MIB Oid for a Enterprise trap 2) is a Trap type; SnmpV1
Sean> or Enterprise

Sean> My question is how can I get acess to this information inside
Sean> scotty?

The scotty API follows the SMIv2 model in which notifications are
identified by an OID rather than the combination of the enterprise,
generic and specific value contained in an SNMPv1 trap message. For
all the little details and pointers to the relevant specs, please take
a look at Dave Perkin's "Questions Answered" column in the March 1998
issue of The SimpleTimes:

http://www.simple-times.org/pub/simple-times/issues/6-1.html#faq

Juergen

-- 